Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3842
FMI: 3

Description: Analog Ground 3 02 Circuit Failed High
Troubleshooting:
DESCRIPTION:
CPC output 3 02 short to voltage.
MONITORED PARAMETER:
CPC Output 3/02.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Key on
POSSIBLE CAUSES:
Faulty wiring

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3842
FMI: 4

Description: Analog Ground 3 02 Circuit Failed Low
Troubleshooting:
DESCRIPTION:
CPC output 3 02 short to ground.
MONITORED PARAMETER:
CPC Output 3/02.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Key on
POSSIBLE CAUSES:
Faulty wiring

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3842
FMI: 5

Description: Analog Ground 3 02 Circuit Open
Troubleshooting:
DESCRIPTION:
CPC output 3 02 open circuit.
MONITORED PARAMETER:
CPC Output 3/02.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Key on
POSSIBLE CAUSES:
Faulty wiring

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3843
FMI: 3

Description: Digital Input 1 01 Circuit Failed High
Troubleshooting:
DESCRIPTION:
CPC input 1 01 short to voltage.
MONITORED PARAMETER:
CPC Output 1/01.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Correct CPC parameter list needs to be installed.
3. Faulty wiring.
4. Parameters need configuring.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3843
FMI: 4

Description: Digital Input 1 01 Circuit Failed Low
Troubleshooting:
DESCRIPTION:
CPC input 1 01 short to ground.
MONITORED PARAMETER:
CPC Output 1/01.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Correct CPC parameter list needs to be installed.
3. Faulty wiring.
4. Parameters need configuring.