Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3858
FMI: 4

Description: Digital Input 2 08 Circuit Failed Low
Troubleshooting:
DESCRIPTION:
CPC input 2 08 short to ground.
MONITORED PARAMETER:
CPC Output 2/08.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Correct CPC parameter list needs to be installed.
3. Faulty wiring.
4. Parameters need configuring.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3859
FMI: 3

Description: Digital Input 4 16 Circuit Failed High
Troubleshooting:
DESCRIPTION:
CPC input 4 16 short to voltage.
MONITORED PARAMETER:
CPC Output 4/16.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Correct CPC parameter list needs to be installed.
3. Faulty wiring.
4. Parameters need configuring.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3859
FMI: 4

Description: Digital Input 4 16 Circuit Failed Low
Troubleshooting:
DESCRIPTION:
CPC input 4 16 short to ground.
MONITORED PARAMETER:
CPC Output 4/16.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Correct CPC parameter list needs to be installed.
3. Faulty wiring.
4. Parameters need configuring.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3860
FMI: 3

Description: Digital Input 4 18 Circuit Failed High
Troubleshooting:
DESCRIPTION:
CPC input 4 18 short to voltage.
MONITORED PARAMETER:
CPC Output 4/18.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Correct CPC parameter list needs to be installed.
3. Faulty wiring.
4. Parameters need configuring.