Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 524279
FMI: 2
Description: Expansion Tank Pressure Sensor Data Erratic
Troubleshooting:
DESCRIPTION:
This code is not configured for NAFTA applications. If this code is active, Common Powertrain
Controller (CPC) configuration is incorrect.
MONITORED PARAMETER:
CPC PGR063
TYPICAL ENABLING CONDITIONS:
Not enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERFICATION:
Key ON engine OFF.
POSSIBLE CAUSES:
1. Faulty CPC.
2. CPC need reprogramming.
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 524279
FMI: 3
Description: Expansion Tank Pressure Sensor Voltage Failed High
Troubleshooting:
DESCRIPTION:
This code is not configured for NAFTA applications. If this code is active, Common Powertrain
Controller (CPC) configuration is incorrect.
MONITORED PARAMETER:
CPC PGR063
TYPICAL ENABLING CONDITIONS:
Not enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERFICATION:
Key ON engine OFF.
POSSIBLE CAUSES:
1. Faulty CPC.
2. CPC need reprogramming.
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 524279
FMI: 4
Description: Expansion Tank Pressure Sensor Voltage Failed Low
Troubleshooting:
DESCRIPTION:
This code is not configured for NAFTA applications. If this code is active, Common Powertrain
Controller (CPC) configuration is incorrect.
MONITORED PARAMETER:
CPC PGR063
TYPICAL ENABLING CONDITIONS:
Not enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERFICATION:
Key ON engine OFF.
POSSIBLE CAUSES:
1. Faulty CPC.
2. CPC need reprogramming.
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 524279
FMI: 11
Description: Expansion Pressure Tank Pressure Set Fault
Troubleshooting:
DESCRIPTION:
This code is not configured for NAFTA applications. If this code is active, Common Powertrain
Controller (CPC) configuration is incorrect.
MONITORED PARAMETER:
CPC PGR063
TYPICAL ENABLING CONDITIONS:
Not enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERFICATION:
Key ON engine OFF.
POSSIBLE CAUSES:
1. Faulty CPC.
2. CPC need reprogramming.