Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 1172
FMI: 3

Description: Turbocharger Compressor Inlet Temperature Sensor or Circuit Failed High
Troubleshooting:
DESCRIPTION:
This fault code sets when there is a short to power or and open in the turbocharger compressor
inlet temperature circuit.
MONITORED PARAMETER:
Turbocharger compressor inlet temperature.
TYPICAL ENABLING CONDITIONS:
Ignition on
MONITOR SEQUENCE:
Always
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
MIL
ENGINE REACTION:
None
VERIFICATION:
Engine running for one minute.
POSSIBLE CAUSES:
1. Damaged Turbocharger Compressor Inlet Temperature electrical connector harness side.
2. Faulty Turbocharger Compressor Inlet Temperature sensor and electrical connector.
3. Damaged pins or connector.
4. Faulty wiring.
Page

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 1172
FMI: 4

Description: Turbocharger compressor Inlet Temperature Circuit Failed Low
Troubleshooting:
DESCRIPTION:
This fault code sets when there is a short to ground in the turbocharger compressor inlet
temperature circuit.
MONITORED PARAMETER:
Turbocharger compressor inlet temperature.
TYPICAL ENABLING CONDITIONS:
Ignition on
MONITOR SEQUENCE:
Always
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
MIL
ENGINE REACTION:
None
VERIFICATION:
Engine running for one minute.
POSSIBLE CAUSES:
1. Damaged Turbocharger Compressor Inlet Temperature electrical connector harness side.
2. Faulty Turbocharger Compressor Inlet Temperature sensor and electrical connector.
3. Damaged pins or connector.
4. Faulty wiring.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 1172
FMI: 21

Description: Compressor Inlet Temperature Sensor Signal Not Plausible
Troubleshooting:
DESCRIPTION:
This fault code sets when the motor control module (MCM) detects that the turbocharger
compressor inlet temperature is greater than 20°C (36°F) degrees from the expected
temperature after the engine has been turned off for 8 hours.
MONITORED PARAMETER:
Compressor inlet temperature.
TYPICAL ENABLING CONDITIONS:
1. Key on.
2. Engine off.
3. Battery voltage greater than 11 volts.
4. Engine rpm at zero.
5. Ambient temperature less than 40°C (104°F).
6. Engine off for no less than 8 hours.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Once per cool down cycle.
TYPCIAL DURATION:
5 seconds
DASH LAMPS:
MIL
ENGINE REACTION:
None
VERIFICATION:
Road test the vehicle for 30 minutes until the coolant reaches operating temperature. Then
verify that the engine compressor inlet temperature is within 10°C (18°F) of the ambient air
temperature.
POSSIBLE CAUSES:
1. Reprogramming or time change to the CPC.
2. Damaged or corroded sensor connectors.

3. Failed sensor.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 1231
FMI: 9

Description: Aftertreatment Control Module Message Not Received or Has Stopped Arriving
Troubleshooting:
DESCRIPTION:
Aftertreatment control module (ACM) message not received or has stopped arriving.
MONITORED PARAMETER:
ACM Controller Area Network (CAN) communication.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
1. MIL is solid.
2. CEL and AWL flash.
ENGINE REACTION:
30 seconds shutdown.
VERIFICATION:
Turn the ignition OFF, disconnect the USB link from the 9-pin connector. Wait five minutes,
reconnect the USB link and the diagnostic tool. Turn the ignition ON and recheck for the fault
code.
POSSIBLE CAUSES:
1. Battery voltage
2. ACM, the Motor Control Module (MCM), or Common Powertrain Controller (CPC) needs
reprogramming.
3. Corroded pins.
4. Damaged pins.
5. Bent pins.
6. Spread pins.
7. Faulty circuits.

8. Faulty ACM.
9. Faulty CPC.
10. Faulty MCM.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)ACM
PID: N/A
SPN: 1231
FMI: 9

Description: Aftertreatment Control Module Message Not Received or Has Stopped Arriving
Troubleshooting:
DESCRIPTION:
This fault code sets when the Motor Control Module (MCM) stops receiving messages from the
Aftertreatment Control Module (ACM).
MONITORED PARAMETER:
ACM Controller Area Network (CAN) communication.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
1. MIL is solid.
2. CEL and AWL flash.
ENGINE REACTION:
30 seconds shutdown.
VERIFICATION:
Turn the ignition OFF, disconnect the USB link from the 9-pin connector. Wait five minutes,
reconnect the USB link and the diagnostic tool. Turn the ignition ON and recheck for the fault
code.
POSSIBLE CAUSES:
1. Over/under voltage supply to the ACM module.
2. Fault set during a reprogram event.
3. Loss of power to the ACM.
4. Loss of ground to the ACM.
5. Loss of ignition switch power to the ACM.
6. Open in the CAN-H/Can-L communication circuit to the ACM.