Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 2023
FMI: 9

Description: J1939 Message is Missing from Source Address 23 (dec)
Troubleshooting:
DESCRIPTION:
J1939 message is missing from source address 23 (dec).
MONITORED PARAMETER:
CAN communication
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
None
ENGINE REACTION:
None
VERIFICATION:
Ignition cycle
POSSIBLE CAUSES:
1. Battery voltage.
2. Faulty Controller Area Network (CAN) line.
3. CPC needs reprogramming.
4. CPC needs proper configuration.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 2025
FMI: 9

Description: J1939 Message is Missing from Source Address 25 (dec)
Troubleshooting:
DESCRIPTION:
J1939 message is missing from source address 25 (dec).
MONITORED PARAMETER:
CAN communication
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
None
ENGINE REACTION:
None
VERIFICATION:
Ignition cycle
POSSIBLE CAUSES:
1. Battery voltage.
2. Faulty Controller Area Network (CAN) line.
3. CPC needs reprogramming.
4. CPC needs proper configuration.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 2033
FMI: 9

Description: J1939 Message is Missing from Source Address 33 (dec)
Troubleshooting:
DESCRIPTION:
J1939 message is missing from source address 33 (dec).
MONITORED PARAMETER:
CAN communication
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
None
ENGINE REACTION:
None
VERIFICATION:
Ignition cycle
POSSIBLE CAUSES:
1. Battery voltage.
2. Faulty Controller Area Network (CAN) line.
3. CPC needs reprogramming.
4. CPC needs proper configuration.

Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 2042
FMI: 9

Description: J1939 message is missing from Source Address 42 (dec)
Troubleshooting:
DESCRIPTION:
J1939 message is missing from source address 42 (dec).
MONITORED PARAMETER:
CAN communication
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
None
ENGINE REACTION:
None
VERIFICATION:
Ignition cycle
POSSIBLE CAUSES:
1. Battery voltage.
2. Faulty Controller Area Network (CAN) line.
3. CPC needs reprogramming.
4. CPC needs proper configuration.