Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)CPC
PID: N/A
SPN: 3511
FMI: 4
Description: Remote Accelerator Pedal Supply Voltage Circuit Failed Low
Troubleshooting:
NOTE: This code sets when the Common Powertrain Controller (CPC) detects the voltage on
the sensor supply circuits is out of range.
DESCRIPTION:
Remote accelerator pedal supply circuit short to ground.
MONITORED PARAMETER:
Remote accelerator pedal voltage.
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
Key on
EXECUTION FREQUENCEY:
None
TYPCIAL DURATION:
None
DASH LAMPS:
CEL
ENGINE REACTION:
Idle only
VERIFICATION:
Ignition key cycle ON.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs proper configuration.
2. Faulty remote throttle switch.
3. Faulty wiring.
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)MCM
PID: N/A
SPN: 3511
FMI: 4
Description: 3V Sensor Supply Bank 1 Circuit Failed Low
Troubleshooting:
NOTE: This code indicated an Motor Control Module (MCM) internal failure. Replace the MCM.
DESCRIPTION:
3V sensor supply bank 1 circuit failed.
MONITORED PARAMETER:
ACM 3V internal power supply.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
2 seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
None
VERIFICATION:
Engine idle (1 minute).
POSSIBLE CAUSES:
Faulty MCM
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3511
FMI: 4
Description: 3V Sensor Supply Bank 1 Circuit Failed Low
Troubleshooting:
DESCRIPTION:
3V sensor supply bank 1 circuit failed.
MONITORED PARAMETER:
ACM 3V internal power supply.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
None
VERIFICATION:
Engine idle: one minute.
POSSIBLE CAUSES:
Faulty ACM
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3511
FMI: 14
Description: Ambient Air Temp Sensor Ground Wire Shorted to Chassis
Troubleshooting:
POSSIBLE CAUSES:
1. Bent pins.
2. Spread pins.
3. Corroded pins.
4. Ambient temperature sensor.
5. Faulty wiring.
Page
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 3512
FMI: 3
Description: 3V Sensor Supply Bank 2 Circuit Failed High
Troubleshooting:
DESCRIPTION:
3V sensor supply bank 2 circuit failed high.
MONITORED PARAMETER:
ACM 3V internal power supply.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
None
VERIFICATION:
Engine idle: one minute.
POSSIBLE CAUSES:
Faulty wiring.