Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 701
FMI: 3
Description: Digital Output 3/07 Circuit Failed High
Troubleshooting:
DESCRIPTION:
Output 3/07 circuit short to power.
MONITORED PARAMETER:
Pin 7 of the CPC #3 connector.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Key ON, engine OFF.
NOTE: The Common Powertrain Controller (CPC) digital outputs have the same SPN as some
Motor Control Module (MCM) faults. The diagnostic tool makes the distinction between the
MCM and CPC when diagnosing a fault.
POSSIBLE CAUSES:
1. Faulty wiring.
2. Parameters need configured.
Page 1
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 701
FMI: 4
Description: Digital Output 3/07 Circuit Failed Low
Troubleshooting:
DESCRIPTION:
Output 3/07 circuit short to ground.
MONITORED PARAMETER:
Pin 7 of the CPC #3 connector.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Key ON, engine OFF.
NOTE: The Common Powertrain Controller (CPC) digital outputs have the same SPN as some
Motor Control Module (MCM) faults. The diagnostic tool makes the distinction between the
MCM and CPC when diagnosing a fault.
POSSIBLE CAUSES:
1. Faulty wiring.
2. Parameters need configured.
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 701
FMI: 5
Description: Digital Output 3/07 Circuit Open
Troubleshooting:
DESCRIPTION:
Output 3/07 open circuit.
MONITORED PARAMETER:
Pin 7 of the CPC #3 connector.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Key ON, engine OFF.
NOTE: The Common Powertrain Controller (CPC) digital outputs have the same SPN as some
Motor Control Module (MCM) faults. The diagnostic tool makes the distinction between the
MCM and CPC when diagnosing a fault.
POSSIBLE CAUSES:
1. Faulty wiring.
2. Parameters need configured.
Make: Detroit
Engine: DD15 GHG17 (2017 & Newer)
PID: N/A
SPN: 702
FMI: 3
Description: Digital Output 3 08 Circuit Failed High
Troubleshooting:
DESCRIPTION:
CPC output 3 08 short to voltage.
MONITORED PARAMETER:
CPC output 3/8.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCEY:
Always enabled
TYPCIAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
POSSIBLE CAUSES:
1. Common Powertrain Controller (CPC) needs reprogramming.
2. Faulty wiring.